aircondlounge/Psychrometric Analysis Course

  • $79.99

Psychrometric Analysis Course

  • Course
  • 18 Lessons

Learn how to size AHU cooling coils and troubleshoot air conditioning problems by analyzing the psychrometrics of various air conditioning processes.

or join the Pro Plan at $20/mo or $220/yr.

Course Outline

Introduction

To start, you'll learn what is the coil load calculator and understand how to read the psychrometric chart. Then, you'll be given to download an excel calculator that will support your progress in this course and future applications.

List of lessons:

Calculator & Chart Explanation
Coil Load Calculator

Part 1: Cooling Coil Sizing

Part 1 is where you'll learn how to determine the on/off coil temperature of a cooling coil in order to calculate the coil capacity based on a given cooling load requirement. You'll also learn how to calculate the heat gain from fan motor and supply/return duct.

List of lessons:

1.1 Sensible Heat Ratio
1.2 Indoor Design Conditions
1.3 Off Coil Temperature
1.4 Fan Motor Heat Gain
1.5 Supply Duct Heat Gain
1.6 Return Path Heat Gain
1.7 Mixed Air Temperature
1.8 On Coil Temperature

Part 2: Design vs Selection

In Part 2, you'll be presented an AHU selection report and the important parameters within the AHU will be explained. Then, you'll learn how the actual selection differ from the design, how to interpret it and what to do about it.

List of lessons:

2.1 AHU Selection Report
2.2 Supply Fan Selection
2.3 Static Pressure & Duct Losses

Part 3: Advance Analysis

Part 3 is about application. You'll go through an air conditioning problem with several scenarios to demonstrate how to use psychrometric analysis in troubleshooting. You'll also learn what factors will affect cooling coil sizing.

List of lessons:

3.1 Cooling Problems
3.2 High Outdoor Airflow

Conclusion

The final section of this course includes a thank you message and takeaways from the instructor, and a course assessment quiz to test your knowledge.

List of lessons:

Course Completion
Course Assessment Quiz
Certificate of Completion

Master the Air Conditioning System

Take control of each air conditioning process, design and deploy the right countermeasures.

Cooling Coil Sizing

Learn how to size the cooling coil of an AHU via the step-by-step video guide presented in the course.

Coil Load Calculator

Use the Excel calculator included in the course to plot the processes and calculate the coil load.

Troubleshooting

Efficiently troubleshoot all air conditioning problems by knowing the system's psychrometrics.

Course Features

Simplicity and actionable result are my principles in teaching.

Video Lessons

Theoretical Explanation

I'll explain in person each of the steps in detail, what are they, what numbers we use and why we use those numbers.

Step-by-Step Guide

Practical Demonstrations

I will also show you exactly how to do the sizing. I'll show you how to plot the steps on the psychrometric chart.

Exclusive Download

Integrated Calculator

By enrolling in this course, you'll get a custom-made Excel calculator that has multiple functions in one.

Practical

Working Example

We don't work on imagination but an actual working example with drawings, load requirement and duct layout.

Real Application

Actual AHU Review

We will use an AHU selection report, compare the numbers to our design, discuss and review the final result.

  • $79.99

Psychrometric Analysis Course

  • Course
  • 18 Lessons

Learn how to size AHU cooling coils and troubleshoot air conditioning problems by analyzing the psychrometrics of various air conditioning processes.

or join the Pro Plan at $20/mo or $220/yr.

Frequently Asked Questions

Where can I attend this course?

The Psychrometric Analysis Course is a pre-recorded online video course. You can attend anytime you want.

Is there a time limit?

No. Once you buy it, you can access for lifetime. You will also receive all future updates to the course.

Will I able to understand?

The Psychrometric Course is designed for easy to understand. All video lessons have english subtitle. If you don't understand any of the lessons, you can refer Yu.

1% of all proceeds go to fund carbon removal.

aircondlounge is a member of Stripe Climate. Your purchase will support the clause.